SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays
SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays
SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays
SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays
SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays
SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays
SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays
SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays
Hover to Zoom

Last Updated
14 Jul 2020
Country Origin
France
Minimum Order
1 unit

Specification of

SCHNEIDER MiCom P122 - 3 Phase Over current and Earth Fault Protection Relays

MiCOM P12x is a range of directional and non-directional overcurrent relays from single phase or earth fault up to the multifunctional three-phase P127 device with voltage protection functions. Models available: MiCOM P120, MiCOM P121, MiCOM P122, MiCOM P123, MiCOM P125, MiCOM P126, MiCOM P127

Features :

MiCOM P12x is housed in a compact 4U case in 20TE or 30TE widths, MiCOM P12x is fully withdrawable to facilitate easy and quick replacement. The dual-rated current input is powered by conventional 1A or 5A Current Transformers. A wide-range power supply allows a flexible auxiliary voltage to be applied from 24-250Vdc/48-240Vac. P122 also offers a compact case solution with reduced hardware and functionality where installation space is minimal.

Software features include 2 settings groups for quick switching between application configurations and customisable reflex automation, allowing logical AND, OR or NOT gates.

MiCOM P12x devices also include a rear RS485 communication port with a variety of protocols; DNP3, IEC 60870-5-103, Modbus and Courier.

Benefits :

Flexible, Simple and Reliable

  • User friendly HMI
  • Reliable solution with more than 100 000 units installed around the world
  • Flexible and simple solution
  • Advanced post fault analysis
  • Withdrawable

Applications :

MiCOM P12x offers a wide range of protection functions allowing its use in many applications including:

  • Main or backup protection on MV/HV systems
  • Overhead lines & underground cables, backup on HV systems.
  • Insulated, solid earthed, resistance earthed, and Petersen coil earthed neutral systems
  • MV subscribers, Industry, Transport
  • Generator and Transformer schemes

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1

Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot